Year : 2017  |  Volume : 4  |  Issue : 2  |  Page : 47-49

A case of atlantoaxial dislocation surgically fixated with laminar craw hooks, spinous plates, and occipital plate system


1 Consultant, Department of Neurosurgery, Jichi Medical University,Saitama Medical Center, Saitama, Japan
2 Consultant, Department of Neurosurgery, Tokyo Rinkai Hospital, Tokyo, Japan
3 Consultant, Department or Neurosurgery, Spine Center, Yachiyo-Hospital, Aichi, Japan

Correspondence Address:
Motoi Shoda
Consultant, Department or Neurosurgery, Spine Center, Yachiyo-Hospital, Aichi
Japan
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.5005/jp-journals-10039-1126

Rights and Permissions

Although cervical screw fixation is often demonstrated as biomechanical outstanding instrumentation for the case of upper cervical instability, only few reports have presented the complicated technique and high risk in the surgery. In this article, we show a case of atlantoaxial dislocation successfully fixated without any cervical screws.